Description
Method of Application
- Using the #3 Phillips tip provided, and a variable speed drill, engage the fastener into the deck as noted below. Do not over or under drive the fastener. Threads must engage the decking material per Technical Specifications.
- Determine screw length as follows:
- Steel Decks: Select fastener length to penetrate through the deck a minimum of 3 ⁄ 4" (19.1 mm).
- Wood Decks: Select fastener length to penetrate into or through the deck a minimum of 1" (25.4 mm).
- Ace #14 Fasteners may not work as expected through existing roof systems or unusual substrates.
- For best results, use a variable-speed screw gun (0-2500 RPM). Do not over tighten.
Storage
Store in original, unopened packaging protected from the weather.
Precautions
Eye protection must be worn during the installation of the fasteners.
FBC: FL41667
Ace Screws’ products and specifications are subject to change without notice. Neither Ace Screws nor its representatives practice architecture/engineering. Ace Screws offers no opinion on and expressly disclaims any responsibility for the soundness of any structure. Ace Screws accepts no liability for structural failure or resultant damages. Consult a competent structural engineer prior to installation if the structural soundness or structural ability to properly support a planned installation is in question. No Ace Screws representative is authorized to vary this disclaimer.
*When installing into 18Ga deck, use a slow, controlled approach and feather the trigger to avoid binding or bit slippage; excessive speed can cause damage to the fastener.
Product Packaging
Screw Length | Thread Length | Pieces per Pail | lbs. Per Package | Packages per Pallet |
---|---|---|---|---|
1-1/4” (31.8 mm) | Full | 1,000 | 14.2 lbs | 80 |
1-1/2” (38.1 mm) | Full | 1,000 | 18.1 lbs | 80 |
2” (50.8 mm) | Full | 1,000 | 22.0 lbs | 80 |
2-1/2” (63.5 mm) | Full | 1,000 | 25.9 lbs | 80 |
3” (76.2 mm) | Full | 1,000 | 29.8 lbs | 80 |
3-1/2” (88.9 mm) | Full | 1,000 | 33.7 lbs | 80 |
4” (101.6 mm) | Full | 1,000 | 37.6 lbs | 80 |
4-1/2” (114.3 mm) | 4” (101.6 mm) | 1,000 | 42.1 lbs | 60 |
5” (127.0 mm) | 4” (101.6 mm) | 1,000 | 46.7 lbs | 60 |
5-1/2” (139.7 mm) | 4” (101.6 mm) | 1,000 | 50.6 lbs | 60 |
6” (152.4 mm) | 4” (101.6 mm) | 1,000 | 54.5 lbs | 60 |
7” (177.8 mm) | 4” (127.0 mm) | 500 | 32.1 lbs | 40 |
8” (203.2 mm) | 4” (127.0 mm) | 500 | 36.0 lbs | 40 |
9” (228.6 mm) | 5” (127.0 mm) | 250 | 21.2 lbs | 20 |
10” (254.0 mm) | 5” (127.0 mm) | 250 | 23.1 lbs | 20 |
11” (279.4 mm) | 5” (127.0 mm) | 250 | 25.1 lbs | 20 |
12” (304.8 mm) | 5” (127.0 mm) | 250 | 27.0 lbs | 20 |
13” (330.2 mm) | 5” (127.0 mm) | 250 | 29.0 lbs | 15 |
14” (355.6 mm) | 5” (127.0 mm) | 250 | 31.0 lbs | 15 |
15” (381.0 mm) | 5” (127.0 mm) | 250 | 32.9 lbs | 15 |
Properties
Property | Typical Performance |
---|---|
Material | Manufactured using SAE 1022 HEAT TREATED STEEL |
Threads/Inch | 13 |
Fastener Tip | High Performance Drill Point |
Fastener Head | #3 Phillips Drive |
Typical properties and characteristics are based on samples tested and are not guaranteed for all samples of this product. This data and information are intended as a guide and does not reflect the specification range for any particular property of this product.
Ace #14 Fastener Minimum Specification (Actual Test Results)
3rd Party Independent: (Nemo Etc. | SGS SA | Element Materials Technology) | Pull Out Test Results | |||
---|---|---|---|---|
ASTM F6096/F606M-2019 | Minimum | Average | Ga, ksi | Average |
Tensile | 2830 lbf | 2874 lbf | 22 Ga, 40 Grade | 515 lbf |
Shear Test | 1571 lbf | 1599 lbf | 22 Ga, 80 Grade | 776 lbf |
Torque Test | 114 lbf-in | 120 lbf-in | 19/32” Plywood | 1397 lbf |
DIN 50018 15 cycles Kesternich | Specification | Average | ||
Black e-coat | <15 % red rust | <5% red rust Exceeds FM 4470 Requirements |